Double Insulated

Applications: Gas Conversions
Conductor: OXYGEN FREE Plain Copper Wire to AS/NZS 1125
Insulation: V90 PVC to AS/NZS 3808
Core Colour: Red
Sheath: 5V90 PVC to AS/NZS 3808
Sheath Colour: Black
Packs: 30, 100, metres, other packs by request
Conductor: OXYGEN FREE Plain Copper Wire to AS/NZS 1125
Insulation: V90 PVC to AS/NZS 3808
Core Colour: Red
Sheath: 5V90 PVC to AS/NZS 3808
Sheath Colour: Black
Packs: 30, 100, metres, other packs by request
| Code | * MM | Strand | Nominal | **AMP | Insulation | Sheath | Electrical | Nominal | Mass |
|---|---|---|---|---|---|---|---|---|---|
| Industry | No. / Size | Area | Rating | Thickness | Thickness | Resistance | O.D. | (kg/100m) | |
| Equiv. | (mm²) | at | (mm) | (mm) | at 20°C | (mm) | |||
| 30°C | (ohm/km) | ||||||||
| AD3 | 3 | 14/0.32 | 1.13 | 20 | 0.4 | 0.8 | 16.5 | 3.8 | 2.75 |
| AD4 | 4 | 23/0.32 | 1.84 | 28 | 0.4 | 0.8 | 10.2 | 4.2 | 3.7 |
| AD6 | 6 | 57/0.32 | 4.59 | 48 | 0.6 | 0.8 | 4.1 | 5.7 | 7.1 |
| * MM is an industry term that identifies cable size and is not CONDUCTOR CROSS SECTION AREA | |||||||||
| ** AMP RATING: TO JASO D609 derating factors apply | |||||||||
| Derating Factors for Bundling of Single Core Cables | |||||||||
| No of Cables | 1 | 2 | 3 | 4 | 5 | 6 to 7 | 8 to 10 | 11 to 12 | |
| Factor | 1 | 0.8 | 0.7 | 0.6 | 0.55 | 0.5 | 0.45 | 0.4 | |
| Derating Factors for Ambient Temperatures °C | |||||||||
| Temperature | 30 | 40 | 50 | 60 | 70 | ||||
| Factor | 1 | 0.9 | 0.76 | 0.6 | 0.45 |