Flat Twin Sheath

TINNED COPPER WIRE (TCW) TO AS1125
Applications: Marine Trailer Wiring, General Purpose Marine Wiring, Lights, Instrumentation
Conductor: Tinned Copper Wire (TCW) to AS1125
Insulation: RoHS Compliant V90 PVC to AS3808
Colours: Red & Black
Sheath Colours: White
Packs: 50, 100 metres – other packs by request
Code | Strand | **MM | Voltage | Nominal | Insulation | Sheath | *AMP | Electrical | Nominal | Mass |
---|---|---|---|---|---|---|---|---|---|---|
No/Size | Industry | Rating | Area | Thickness | Thickness | Rating | Resistance | O.D. | (kg/100m) | |
Equivalent | (mm²) | (mm) | (mm) | JASO D609 | at 20°C | (mm) | ||||
at 30°C | (ohm/km) | |||||||||
MW3 | 14/0.32 | 3 | 120V DC | 1.13 | 0.4 | 0.6 | 16 | 16.7 | 3.3 x 5.5 | 4.1 |
MW4 | 23/0.32 | 4 | 120V DC | 1.84 | 0.4 | 0.6 | 22 | 10.2 | 3.8 x 6.3 | 6.1 |
MW6 | 57/0.32 | 6 | 120V DC | 4.5 | 0.6 | 0.8 | 38 | 4.15 | 5.7 x 9.6 | 14 |
** MM – is an industry term that identifies cable size and is not CONDUCTOR CROSS SECTION AREA | ||||||||||
Derating Factors for Bundling of Single Core Cables | ||||||||||
No of Cables | 1 | 2 | 3 | 4 | 5 | 6 to 7 | 8 to 10 | 11 to 12 | ||
Factor | 1 | 0.8 | 0.7 | 0.6 | 0.55 | 0.5 | 0.45 | 0.4 | ||
* AMP RATING: TO JASO D609 derating factors apply | ||||||||||
Derating Factors for Ambient Temperatures °C | ||||||||||
Temperature | 30 | 40 | 50 | 60 | 70 | |||||
Factor | 1 | 0.9 | 0.76 | 0.6 | 0.45 |